MalcoEdgeâ„¢ A2L 2 Valve Manifold Kit, R32, R410A, R454B, 1/4 in. Storage Ports (M2VKA2L14)
The MalcoEdgeâ„¢ 2-Valve Analog Manifold Kit is an 80mm gauge manifold for A2L split-system diagnostics, packed in a case with the SS7214 Safe Seal 3-piece hose set with 1/4 in. SAE fittings. The manifold has 1/4 in. SAE hose storage ports on the sides to match technicians working with 1/4 in. connection hoses.
The manifold has 1/4-turn ball valves and an integrated sight glass. The Class 1 accuracy gauges (plus or minus 1% full scale) read to 500 psi full scale on the low side and 800 psi on the high side. Gauge bumpers help protect the gauges, and a flexible mounting strap with mechanical and magnetic hanging options gives you a place to hang the manifold on the job. Manifold port connections are 1/4 in. SAE.
The included hose set (SS7214) is a 3-piece, 72 in., 1/4 in. x 1/4 in. Safe Seal hose set with a Safe Seal anti-blowback design that helps prevent refrigerant spray or loss when disconnecting.
This version is for A2L refrigerants, R32, R410A and R454B.
Features
- 80mm Class 1 gauges, accurate to within 1% of full scale, at 500 psi low side and 800 psi high side
- Comes in a case with 1/4 in. x 1/4 in. Safe Seal hoses, 3 pieces at 72 in. long
- Side hose storage ports, 1/4 in. SAE, matched to 1/4 in. connection hoses
- 1/4-turn ball valves, plus an integrated sight glass
- Gauge bumpers for protection, plus a flexible strap that hangs mechanically or magnetically
- For A2L refrigerants, R32, R410A and R454B; 1/4 in. SAE manifold port connections
FAQs
Q1: Should I dedicate a gauge set to a specific refrigerant or clean them between service calls?
A1: We recommend dedicating a manifold to each refrigerant for efficiency. Alternatively, clean and flush your manifolds when switching between refrigerants.
Q2: Do you offer manifold recalibration?
A2: No, manifold recalibration is not available. The gauges include a calibration screw that lets you re-zero them if they are slightly out of calibration due to altitude changes or wear over time. If you are unable to readjust the zero position, Malco recommends replacing any gauge that has drifted too far outside of calibration. Replacement gauges for this product are RGLSA2L80 and RGHSA2L80.
Q3: What is unique about MalcoEdge manifolds?
A3: MalcoEdge ball valves are spring-loaded, making the seals last longer. Compared to traditional multi-turn piston valves, the ball valves open and close quickly and easily.
Q4: Which refrigerant saturation temperatures are printed on these gauges?
A4: R32, R410A, R454B
Q5: Do I need to flush and clean my equipment when switching between refrigerants?
A5: Some refrigerants cannot be mixed because they use different lubricants. As a best practice, flush the pumps, hoses, manifolds, and other components with a cleaner to ensure they do not cross-contaminate. We recommend flushing the system with ACE Powerflush between services.
Q6: What size are the keeper ports on this manifold?
A6: 1/4″