MalcoEdgeâ„¢ High Side R32/R410A/R454B Single Gauge Analog Manifold (MSHA2L)

The Where To Buy map requires marketing cookies to be accepted. Please change your cookie preferences by clicking here and accepting cookies.


The MalcoEdgeâ„¢ High Side Single Gauge Analog Manifold is for jobs where you only need to check the high side of a system. It is most often used on smaller self-contained refrigeration systems, and it is also useful on larger commercial units where a full manifold would pull more refrigerant than the job needs. Because it pulls only the minimum refrigerant charge necessary, it suits diagnosing and repairing critical charge systems.

It includes two 36 in. Safe Seal hoses (red and yellow) for control and minimal refrigerant loss. A gauge protection bumper guards the gauge, and a flexible mounting strap with mechanical and magnetic hanging options gives you a place to hang it. The Class 1 accuracy gauge (plus or minus 1% full scale) reads to 800 psi full scale, and the manifold port connection is 1/4 in. SAE.

This A2L version is for R32, R410A and R454B refrigerants.

Features

  • Single gauge manifold built for high side only checks on a system
  • Takes only the minimum refrigerant needed for diagnosis and repair of critical charge systems
  • Comes with a pair of red and yellow 36 in. Safe Seal hoses, for control and low refrigerant loss
  • Class 1 gauge reads up to 800 psi and stays accurate to within 1% of full scale
  • Gauge bumper for protection, and a flexible strap that hangs mechanically or magnetically
  • A2L version for R32, R410A and R454B refrigerants; 1/4 in. SAE manifold port connection

FAQs

Q1: Should I dedicate a gauge set to a specific refrigerant or clean them between service calls?

A1: We recommend dedicating a manifold to each refrigerant for efficiency. Alternatively, clean and flush your manifolds when switching between refrigerants.

Q2: Do you offer manifold recalibration?

A2: No, manifold recalibration is not available. The gauges include a calibration screw that lets you re-zero them if they are slightly out of calibration due to altitude changes or wear over time. If you are unable to readjust the zero position, Malco recommends replacing any gauge that has drifted too far outside of calibration. The replacement gauge for this product is RGHSA2L80.

Q3: What is unique about MalcoEdge manifolds?

A3: MalcoEdge valves are spring-loaded, making the seals last longer.

Q4: Do I need to flush and clean my equipment when switching between refrigerants?

A4: Some refrigerants cannot be mixed because they use different lubricants. As a best practice, flush the pumps, hoses, manifolds, and other components with a cleaner to ensure they do not cross-contaminate. We recommend flushing the system with ACE Powerflush between services.

Q5: What size are the keeper ports on this manifold?

A5: 1/4″