MalcoEdge™ ESBV6014516 Easy Seal HVAC Hose Set
The MalcoEdge™ ESBV6014516 Easy Seal 60-Inch Hose Set with Ball Valve is a professional-grade solution for servicing mini-split and residential HVAC systems with mixed connection sizes. Featuring 1/4 SAE x 5/16 SAE patented 360 degree swivel female fittings and an integrated ball valve, this hose gives you full control of refrigerant flow for safer, cleaner charging and recovery. Its extended length adds versatility for larger installations, while the rugged construction handles high-pressure applications with ease.
Features
- Ideal for servicing larger or more complex HVAC and refrigeration systems.
- 1/4 SAE x 5/16 SAE Fittings – Designed for compatibility with both standard and mini-split systems.
- Easy Seal Design – Reduces the risk of leaks with patented 360 degree swivel and ensures secure refrigerant transfer.
- Built-In Ball Valve – Provides precise refrigerant flow control and improved safety during service.
- Barrier 4-layer hose meets SAE J2196 and withstands A2L high-pressure use in tough environments.
FAQs
Q: What do I do if the seals on my Easy Seal hoses leak?
A: Malco sells replacement seals to allow you to replace your seals in the field and
extend the life of your hoses.
Q: Does hose length matter when pulling a vacuum?
A: Yes, the shorter the hose and the larger the diameter, such as a 3/8″ MalcoEdge
Turbo Flow hose will be more efficient when vacuum is pulled.
Q: Can I use the same hoses with a variety of refrigerants?
A: MalcoEdge hoses are compatible with popular refrigerants however we do not
recommend using multiple refrigerants in the same hoses unless you take the time
to flush the hoses using a product such as ACE Powerflush. Alternatively, we
recommend you use different hoses for specific refrigerants to prevent cross
contamination of refrigerants from oils remaining in the hoses.
Q: Do I need to flush and clean my equipment when switching between refrigerants?
A: Some refrigerants cannot be mixed as they use different lubricants. As a best practice,
the hoses, manifolds, and other components need to be flushed using a cleaner to ensure
they do not cross contaminate. We recommend flushing the system with ACE Powerflush
between services.
Q: What are the working and burst pressures for these hoses?
A: The working pressure pressure is 800 PSI and the burst pressure is 4000 PSI.
Q: What do I do if my hoses are either engaging a Schrader valve too early or not
engaging a valve enough to fully open the valve?
A: The core depressors are threaded. Adjust the height of the core depressor by screwing
further in or out.