MalcoEdgeâ„¢ Low Side Multi-Gas Single Gauge Manifold R22, R134A, R404A, R407C (MSLMG)
The MalcoEdgeâ„¢ Low Side Multi-Gas Single Gauge Analog Manifold is for jobs where you only need to check the low side of a system. It is most often used on smaller self-contained refrigeration systems, and it is also useful on larger commercial units where a full manifold would pull more refrigerant than the job needs. Because it pulls only the minimum refrigerant charge necessary, it suits diagnosing and repairing critical charge systems.
It includes two 36 in. Safe Seal hoses (yellow and blue) for control and minimal refrigerant loss. A gauge protection bumper guards the gauge, and a flexible mounting strap with mechanical and magnetic hanging options gives you a place to hang it. The Class 1 accuracy gauge (plus or minus 1% full scale) reads to 500 psi full scale, and the manifold port connection is 1/4 in. SAE.
This multi-gas version is for R22, R134A, R404A and R407C refrigerants.
Features
- Single gauge manifold built for low side only checks on a system
- Takes only the minimum refrigerant needed for diagnosis and repair of critical charge systems
- Comes with a pair of yellow and blue 36 in. Safe Seal hoses, for control and low refrigerant loss
- Class 1 gauge reads up to 500 psi and stays accurate to within 1% of full scale
- Gauge bumper for protection, and a flexible strap that hangs mechanically or magnetically
- Multi-gas version for R22, R134A, R404A and R407C refrigerants; 1/4 in. SAE manifold port connection
FAQs
Q1: Should I dedicate a gauge set to a specific refrigerant or clean them between service calls?
A1: We recommend dedicating a manifold to each refrigerant for efficiency. Alternatively, clean and flush your manifolds when switching between refrigerants.
Q2: Do you offer manifold recalibration?
A2: No, manifold recalibration is not available. The gauges include a calibration screw that lets you re-zero them if they are slightly out of calibration due to altitude changes or wear over time. If you are unable to readjust the zero position, Malco recommends replacing any gauge that has drifted too far outside of calibration. The replacement gauge for this product is RGLSMG80.
Q3: What is unique about MalcoEdge manifolds?
A3: MalcoEdge valves are spring-loaded, making the seals last longer.
Q4: Do I need to flush and clean my equipment when switching between refrigerants?
A4: Some refrigerants cannot be mixed because they use different lubricants. As a best practice, flush the pumps, hoses, manifolds, and other components with a cleaner to ensure they do not cross-contaminate. We recommend flushing the system with ACE Powerflush between services.
Q5: What size are the keeper ports on this manifold?
A5: 1/4″